1. 限流孔(kong)板的(de)工作(zuo)原理(li)及(ji)分類
在(zai)石油化工裝置中,限(xian)(xian)流孔板(ban)用于限(xian)(xian)制流體(ti)的(de)流量或降低流體(ti)的(de)壓(ya)力(li),但通常用于工藝物料壓(ya)力(li)降要求(qiu)精度(du)不(bu)高(gao)的(de)場合。
限(xian)流(liu)孔(kong)(kong)板(ban)為同心(xin)銳孔(kong)(kong)板(ban),流(liu)體(ti)(ti)通過孔(kong)(kong)板(ban)就會產生壓(ya)(ya)差,流(liu)量隨壓(ya)(ya)差的增(zeng)大而增(zeng)大。但(dan)當壓(ya)(ya)差超過一定(ding)數(shu)值,即超過臨(lin)界壓(ya)(ya)差時,不論壓(ya)(ya)差如何(he)增(zeng)加(jia),流(liu)量將維持一定(ding)的數(shu)值而不再增(zeng)加(jia)。限(xian)流(liu)孔(kong)(kong)板(ban)就是(shi)根據這個原理來限(xian)制流(liu)體(ti)(ti)的流(liu)量或降(jiang)低流(liu)體(ti)(ti)的壓(ya)(ya)力。限(xian)流(liu)孔(kong)(kong)板(ban)按孔(kong)(kong)板(ban)上開孔(kong)(kong)數(shu)分(fen)為單(dan)(dan)孔(kong)(kong)板(ban)和多孔(kong)(kong)板(ban);按板(ban)數(shu)可分(fen)為單(dan)(dan)板(ban)和多板(ban)。
2. 限(xian)流(liu)孔板的應用
①. 蒸(zheng)(zheng)(zheng)(zheng)汽(qi)吹掃(sao)管路,為了保證(zheng)(zheng)既(ji)能達到連續(xu)吹掃(sao),又保證(zheng)(zheng)提供(gong)最小(xiao)蒸(zheng)(zheng)(zheng)(zheng)汽(qi)流(liu)量的(de)目的(de),設計(ji)中在蒸(zheng)(zheng)(zheng)(zheng)汽(qi)管線設置限(xian)流(liu)孔板,一方面限(xian)制蒸(zheng)(zheng)(zheng)(zheng)汽(qi)流(liu)量,另一方面降低了蒸(zheng)(zheng)(zheng)(zheng)汽(qi)的(de)壓(ya)力,保證(zheng)(zheng)了管路的(de)暢通和安全運(yun)行。
②. 儲罐保(bao)壓。
③. 管線壓力平衡。
④. 在(zai)(zai)管(guan)道中(zhong)閥(fa)門(men)上、下游需要(yao)有較大壓降時,為減少(shao)流體對閥(fa)門(men)的沖蝕,當經孔(kong)(kong)板節流不會產(chan)生氣相時,可在(zai)(zai)閥(fa)門(men)上游串聯孔(kong)(kong)板。
⑤. 流體(ti)需要小流量且(qie)連續流通的(de)(de)地方(fang),如泵的(de)(de)沖洗管(guan)(guan)道、熱備用泵的(de)(de)旁路管(guan)(guan)道(低流量保護管(guan)(guan)道)、分(fen)析取樣管(guan)(guan)等場(chang)所。
⑥. 需要降壓以(yi)減少噪聲或磨損的地方,如放空系(xi)統。
限(xian)流孔板(ban)的安裝見圖 2.188
在熱水分配站配管設計過程中,在同一個熱水分配站上的熱水伴管當量長度宜大致相等,最短熱水伴管當量長度不宜小于最長伴管當量長度的70%,否則宜設置限流孔板或截(jie)止閥(fa)以控制熱水量分配均勻。
3. 孔(kong)板流量計的布置
節流裝置一般安裝在水平管道上,如果必須在垂直段上,則液體流向必須由下向上,氣體流向必須由上向下。節流裝置應盡量安裝在維修方便的地方,要求的直管段長度內不應有焊縫、閥門、管(guan)件(jian)支管和大小頭等。