不銹鋼反(fan)應(ying)器(qi)與(yu)(yu)提供(gong)反(fan)應(ying)熱(re)量的(de)(de)(de)(de)加熱(re)爐或(huo)取走反(fan)應(ying)熱(re)的(de)(de)(de)(de)換熱(re)器(qi),可視為(wei)一(yi)個系統(tong),沒(mei)有(you)防(fang)火(huo)(huo)間(jian)(jian)(jian)(jian)距(ju)的(de)(de)(de)(de)要求。反(fan)應(ying)器(qi)與(yu)(yu)加熱(re)爐的(de)(de)(de)(de)間(jian)(jian)(jian)(jian)距(ju),在(zai)防(fang)火(huo)(huo)規(gui)范和(he)設備(bei)布(bu)置(zhi)設計通則(ze)中規(gui)定為(wei)4.5m,這(zhe)是因為(wei)在(zai)反(fan)應(ying)器(qi)與(yu)(yu)加熱(re)爐之間(jian)(jian)(jian)(jian)只(zhi)留出通道(dao)和(he)管(guan)道(dao)布(bu)置(zhi)及檢修需要的(de)(de)(de)(de)空間(jian)(jian)(jian)(jian)即可。據(ju)統(tong)計國內外11個裝置(zhi)的(de)(de)(de)(de)設備(bei)布(bu)置(zhi)間(jian)(jian)(jian)(jian)距(ju),反(fan)應(ying)器(qi)與(yu)(yu)加熱(re)爐之間(jian)(jian)(jian)(jian)凈距(ju)大于4.5m的(de)(de)(de)(de)有(you)8個,小于4.5m的(de)(de)(de)(de)3個,大于4.5m的(de)(de)(de)(de)往(wang)往(wang)是二者(zhe)之間(jian)(jian)(jian)(jian)有(you)管(guan)廊或(huo)有(you)一(yi)排單柱管(guan)架。按GB 50160《設備(bei)、建(jian)筑物平面布(bu)置(zhi)的(de)(de)(de)(de)防(fang)火(huo)(huo)間(jian)(jian)(jian)(jian)距(ju)》的(de)(de)(de)(de)規(gui)定,明火(huo)(huo)設備(bei)與(yu)(yu)操作溫度(du)等于或(huo)高于自燃點的(de)(de)(de)(de)工藝設備(bei)的(de)(de)(de)(de)凈距(ju)為(wei)4.5m。


  在催化(hua)裂(lie)化(hua)裝(zhuang)置(zhi)(zhi)中(zhong),反(fan)應(ying)器(qi)與再生器(qi)的(de)布置(zhi)(zhi)是由催化(hua)劑循環(huan)線(xian)的(de)尺寸要求(qiu)確(que)定的(de)。按照流化(hua)輸送管道(dao)的(de)最佳(jia)流動條件確(que)定其高(gao)度和位置(zhi)(zhi),這樣反(fan)應(ying)器(qi)和再生器(qi)相對位置(zhi)(zhi)及安裝(zhuang)高(gao)度也就確(que)定下來。一(yi)般反(fan)應(ying)器(qi)與再生器(qi)中(zhong)心線(xian)對齊。


  對(dui)于內部(bu)裝有攪拌或輸送(song)機械(xie)的(de)反應器,應在(zai)頂部(bu)或側面留出攪拌或輸送(song)機械(xie)的(de)軸和電(dian)動機的(de)拆卸、起吊等檢(jian)修(xiu)所(suo)需的(de)空間和場地。